SECTION 412-00: Climate Control System — General Information
2002 Escape Workshop Manual
GENERAL PROCEDURES
Procedure revision date: 06/14/2001

Manifold Gauge Set Connection

Special Tool(s)
R-134a Manifold Gauge Set
176-R032A or equivalent
  1. Turn both valves on the R-134a Manifold Gauge Set all the way to the left to close the low-pressure and high-pressure hoses to the center manifold and center hose.
  1. Remove the A/C charging valve cap (19D702) from the low-pressure service gauge port valve.
  1. Remove the A/C charging valve cap from the high-pressure service gauge port valve.
  1. Connect the R-134a manifold gauge set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
  1. Connect the R-134a manifold gauge set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.