Section 12-02: Heating and Defrosting | 1996 F-150, F-250, F-350, F-Super Duty and Bronco, F-Super Duty Motorhome Chassis Workshop Manual |
| Blower Motor Current Draw and Voltages | ||
|---|---|---|
| Switch Setting | Amps | Volts |
| Low | 3-5 | 3-4 |
| Medium Low | 6-8 | 5-7 |
| Medium High | 10-14 | 7-10 |
| High | 15-22 | 11-14 |
| Control Assembly, Illumination | One ICP-161 Bulb | |
| Blower Circuit System Protection | 30 Amp Mini-Fuse (Light Green) in Panel F-14 (D9ZB-14A094-GA) | |
| Description | Nm | Lb-Ft | Lb-In |
|---|---|---|---|
| Heater Hose Clamps | 2-3 | — | 18-27 |
| Heater Air Plenum Chamber Screws | 2.5-3.0 | — | 22-27 |
| Heater Hose Bracket Retaining Screw | 7-11 | — | 62-97 |
| A/C Manifold and Tube Retaining Bolt | 17-23 | 13-17 | — |