Section 14-02A: Generator, Integral Rear Mounted Regulator, Internal Fan Type, 95 Ampere and 130 Ampere | 1996 F-Series, Bronco Workshop Manual |
Removal
Disconnect battery ground cable (14301).
Disconnect electrical connectors from generator (GEN) (10346).
Remove drive belt (8620).
Remove generator retaining bolts (3).
Remove generator.

| Item | Part Number | Description |
|---|---|---|
| 1 | — | Fuel Filter Assembly (Part of 9K601) |
| 2 | 19703 | A/C Compressor |
| 3 | 8146 | Fan Shroud |
| 4 | 10A313 | Generator Bracket |
| 5 | 10346 | Generator |
| 6 | 389706-S2 | Generator Retaining Bolts (3) |
| 7 | — | Heater Hose Clip |
| 8 | — | Heater Hose |
| A | — | Tighten to 21-29 Nm (16-21 Lb-Ft) |
Installation
Install generator.
Install generator retaining bolts (3). Tighten bolts to 21-29 Nm (16-21 lb-ft).
Install drive belt.
Connect electrical connectors to generator.
NOTE: When the battery (10655) has been disconnected and reconnected, some abnormal drive symptoms may occur while the powertrain control module (PCM) (12A650) relearns its adaptive strategy. The vehicle may need to be driven 16 km (10 miles) or more to relearn the strategy.
Connect battery ground cable.